XTP600 Series

Maximum Sample Pressure: Atmospheric to maximum of 0.3 MPa (3 bar)
Maximum Sample Temperature: 45°C max (higher temperature on request)
Accuracy: Better than ±1% of span
  • Best-in-class accuracy of less than 1% FS allows re-ranging with no need for re-calibration
  • Best-in-class zero or span stability: better than 0.25% of span per month
  • Innovative sensor design means no zero shift and eliminates background gas effects
  • Increased protection against contamination
  • Two 4-20 mA inputs for process variables allows active compensation
  • Two isolated outputs and a local display in an explosion-proof enclosure allow local as well as remote installation
  • Lowest cost of ownership due to minimal maintenance
Measurement Technology: Thermo-paramagnetic oxygen sensor
Gas: Process and non-condensing sample
Measurement Range: Selectable from 0 to 1% to 0 to 25% oxygen (other ranges available on request, eg 0-100% or suppressed ranges)
Response Time (T90): Standard response: 70 seconds, EN 50104: 45 seconds. For fast response consult factory
Repeatability: ±0.2% of span
Linearity: ±0.5% of span for ranges greater than 0-5%
<±1% of span for ranges less or equal to 0-5%
Zero Stability: ±0.25% of span per month
Span Stability: ±0.25% of span per month
Sample Flow Rate: 0.4 l/min for the sensor cell
- Цена: договорная у.е. ( This e-mail address is being protected from spambots. You need JavaScript enabled to view it. )
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

XZR500 & XCU500

Maximum Sample Pressure: Depending on application
Maximum Sample Temperature: Up to 1300°C on request
Accuracy: Better than ± 2% of reading
  • Reliable and repeatable measurements
  • Simple to maintain, easy to calibrate
  • Robust design
  • Quick and easy to install
  • Simple to use
Gas: Wet, dirty and hot
Measurement Range: 0.01 % to 25 % Oxygen
Response Time: < 15 sec for 90% of response step from calibration gas inlet
Repeatability: ± 0.1%
Fidelity: 1% per month
Linearity: Better than ± 1%
Sample Flow Rate: Flue gas at 0.5m/sec minimum rate
- Цена: договорная у.е. ( This e-mail address is being protected from spambots. You need JavaScript enabled to view it. )
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

XZR400TS Series

Maximum Sample Pressure: 3 barg
Maximum Sample Temperature: 100°C
Accuracy: < 2% of reading
Gas: Clean and Dry
Measurement Range: 0.01 ppm to 25% Oxygen (up to 100% optional)
Response Time: < 1 sec (for 90% of the step change)
Repeatability: ±0.1%
Linearity: Better than ±1%
Sample Flow Rate: 1 to 3 l/h with built-in fast loop
Atmospheric Pressure Compensation: Built-in as standard
- Цена: договорная у.е. ( This e-mail address is being protected from spambots. You need JavaScript enabled to view it. )
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.